Co2 Fractional Laser · Scar Removal; Pigmentation Removal; Female Health
Fractional Co2 Laser Machine
Model: QM-10600+
Professional Fractional CO2 Laser Machine Professional fractional CO2 laser machines are widely used to improve a variety of skin conditions, including wrinkles, fine lines, photodamage, uneven pigmentation, skin laxity, as well as scars, skin tags, and benign superficial tumors.
Read the full overviewPricing
Available upon inquiry
Competitive factory-direct pricing
Why order from ZENLASE?
- Written quotation
- Certificate copies sent before you order
- Consumables & spare parts supplied long-term
- Operator training materials in the languages agreed for your order
- One contact from quote to after-sales
Product Overview
Professional Fractional CO2 Laser Machine
Professional fractional CO2 laser machines are widely used to improve a variety of skin conditions, including wrinkles, fine lines, photodamage, uneven pigmentation, skin laxity, as well as scars, skin tags, and benign superficial tumors. By creating regularly spaced microthermal damage zones (MTZs) within the epidermis and superficial dermis, they remove damaged tissue while stimulating collagen and elastic fiber reconstruction, preserving surrounding skin intact for accelerated healing and a shortened downtime. Treatment strategies can be flexibly adjusted based on target tissue depth and anticipated downtime.
Professional fractional CO2 laser machines combine adjustable power output, a precise balance of non-ablative and thermal effects, and a variety of probes and treatment modes to achieve more precise energy distribution for diverse indications, including acne, pigmentation, scar revision, anti-aging, and soft tissue coagulation. CO2 laser machines allow clinicians to precisely control the ablation volume and depth, and control heat through pulse duration and energy delivery mode, enhancing treatment effectiveness while minimizing unnecessary tissue damage.
How Fractional CO2 Laser Machine Work
What is a fractional co2 laser machine?
CO2 laser light has a wavelength of 10.6μm and is completely absorbed by water-rich human tissue (suitable for a range of skin types with settings selected by a trained operator). It converts this energy into heat, causing localized vaporization (ablation) and thermal coagulation. The system utilizes a sealed CO2 laser source that delivers focused energy via an articulating light-guide arm. This configuration allows for high directional accuracy and ensures high energy density at the treatment site.
CO2 lasers operate in the invisible infrared wavelength range, requiring aiming to ensure visibility of the treatment beam. When the laser beam passes through a focusing lens, the heat generated vaporizes the target tissue.
Fractional Output Technology
In fractional laser resurfacing, the laser beam is broken down into numerous tiny microbeams. These beams are separated so that when they strike the skin surface, small areas of skin between the beams remain untouched and undamaged. These untreated areas of skin promote faster recovery and healing, and reduce the risk of complications. Fractional microbeams treat small areas, called microtreatment zones, creating sufficient laser damage to stimulate new collagen production and ultimately rejuvenate facial skin.
The system's specialized articulated arm probe, featuring automated 360° rotation, enables precise intra-vaginal treatment. It delivers controlled thermal energy (50-70°C) at specific depths within the vaginal mucosa.

CO2 laser machines utilize a 10,600nm wavelength, making them ideal for collagen matrix renewal and the treatment of a variety of skin conditions. our factory's CO2 laser machines offer five different probes for efficient, high-precision fractional and non-fractional laser treatments.
Application
The QM-10600+ CO2 fractional laser is a versatile platform designed for comprehensive aesthetic and therapeutic applications. It effectively targets

1)Tighten vagina-Fast tightening, lasting constriction, tightness to improve 60%;
2)Clean the vagina - Deep anti-aging, young level to improve 80%;
3)Moist vagina - Improving secretion, moisture level to improve 80%;
Traditional Fractional Model and Surgical Mode:
1) Skin renewing and resurfacing
2) Wrinkle removal, skin tightening
3) Acne and scar removal, melasma removal
4) Smooth scars like burn, surgery, traumatic, and stretch marks, etc
5) Remove intractable chloasmas and pigmentation
6) Sun damage recovery
Physicians maintain precise control over critical treatment parameters – including ablation depth, thermal exposure, pulse duration, and energy delivery modes – enabling customized protocols for each indication. This granular adjustability optimizes clinical outcomes while preserving surrounding tissue integrity and minimizing collateral damage.
Scan Modes
CO2 fractional laser systems offer three scan modes
- Normal mode
In normal mode, the laser points will be emitted in sequence in rows.
- Midsplit mode
In the Midsplit mode, the laser points will be emitted in two rows in sequence, with the middle serving as the dividing line.
- Random mode
In the Randon mode, the laser points will randomly be emitted within the selected range without repetition until the complete pattern is completed.

Fractional therapy is ideal for skin resurfacing and rejuvenation, including scar treatment, improving skin tone, elasticity, and texture, and reducing epidermal pigmentation.
Unlike ablative laser resurfacing, which removes the entire epidermis, our factory's fractional CO2 laser machine uses fractional delivery technology to create pixel-sized perforations in the skin, leaving intact skin tissue as a"bridge"around the perforations. This intact skin provides a source for rapid epithelial regeneration and repair, promoting new collagen production, tissue regeneration, and contracture of existing fibers while wounds heal.
Fractional treatments are controllable, reducing the risk of adverse side effects such as delayed hypopigmentation, scarring, post-inflammatory hyperpigmentation, infection, and persistent erythema. Patients also enjoy a shorter recovery period and increased comfort.
CO2 Laser Machine Handpiece
A treatment head specifically designed for non-surgical vaginal tightening and mucosal regeneration.



Fractional Laser
Versatile fractional laser for efficient ablation procedures, including skin texture and pigmentation reduction.
The ergonomically designed fractional CO2 laser offers effortless operation and carbon-free ablation technology. It offers a variety of scanning options, including square, rectangular, triangular, hexagonal, circular, elliptical, and linear, enabling rapid coverage of large areas (maximum scanning area approximately 20 mm × 20 mm), making it suitable for a variety of dermatological, cosmetic, and surgical applications.
Ultra-Pulse Handpiece
Perfectly controlled cutting and coagulation, ideal for surgical procedures.
The professional CO2 laser machine's Ultra-Pulse handpiece combines cutting and coagulation functions in one device, allowing surgeons to perform both cutting and coagulation simultaneously without switching handles or parameters during the procedure.
In"Cutting"(ablation) mode, pulses deliver high peak power for immediate tissue ablation. In"Coagulation"(thermal coagulation) mode, longer pulses deliver low to medium power, generating heat that causes vessel and tissue constriction. This sequential action pulse allows the physician to achieve optimal tissue incision or resection while minimizing bleeding and reducing patient downtime. A fixed-focus applicator with two spot sizes enables precise soft tissue cutting.


High-Efficiency Korean Laser Guide Arm - <12% photon loss rate for consistent energy delivery.
Advantages of QM-10600+, Co2 Fractional Laser Machine
- Top Level Metal RF Tube - Even output energy, deeper penetration (8-10mm under the skin). Long lifespan: 8-12 years.
- Multi-Functional Applicators - Specialized handpieces for precise, indication-specific treatments.
- Fractional Mode (Fractional Head) - Targets scar revision (acne, surgical, traumatic), pigmentary lesions (age spots, freckles), wrinkles, skin rejuvenation, acne, and striae (stretch marks).
- Normal Mode (Ultra Pulse Head) - Delivers shorter, faster energy pulses for surgical applications: wart ablation, benign tumor excision, and precision tissue incision.
- Fractional + Ultra Pulse + Vaginal 3 in 1 system
- 360 Vaginal Handle - Automatically Rotating Technology
- Integrated Aiming System - Visible red diode laser (635nm, 2mW) for real-time treatment guidance.
- High Clearance Efficiency - Fragments target chromophores into micro-particles for rapid elimination.
- Customizable Beam Patterns - Adjustable spot size and geometry for tailored lesion coverage.
- Delicate Tissue Safety - Optimized for sensitive anatomical zones (e.g., periorbital, mucosal).
- 7 Programmable Scanning Shapes - Scalable fractional patterns (0.1×0.1mm to 20×20mm) enable area-specific treatment with minimized hypopigmentation risk.
- US Coherent Laser Generator - Premium-grade emission source supporting beam stability and clinical reliability.
- Taiwan Meanwell Power Supply - Stable voltage regulation for uninterrupted operation and extended system longevity.
- Versatile for high ROI - Multi-indication capability maximizes clinical utility and practice revenue.
Before And After

As the skin begins to heal (which takes approximately three weeks), your patient's skin will develop a light pink tint. During this time, you'll begin to see improvements in skin texture and tone. However, the full effects may not be apparent until three to six months after the initial treatment.
| Laser type | RF Tube (USA Coherent) |
| Output power | 1-60W |
| Wavelength | 10.6μm, far-infrared laser |
| Display | 10.4 inch color touch LCD screen |
| System & Probes | 3 systems, 5 probes |
| Pulsed Radio Frequency | 0.530W |
| Scan Graphics | Square, Rectangle, Circle, Triangle, Ellipse, Hexagon, Line It can also be freely deformed based on the above. |
| Scan Graphic Size | 0.1x0.1mm ~ 20x20mm |
| Scan mode (3 modes) | Normal, Midsplit, Random |
| Working State | Hyper-pulsed mode |
| Pulse Duration | 0.1-10 ms |
| Pulse energy | 10mj to 130mj is optional for each dot |
| Spot Distance | 0.1-2.6 mm |
| Interval | 0-6s |
| Repeat | 1-5000 ms |
| Overlap | 1-20 times |
| Condenser Focus | F=50mm |
| Beam divergence Angle | 0.3mrad |
| Spot Size | 0.01mm at the focus |
| Aiming Beam | Less than 2Mw, 635nm red semiconductor laser |
| Beam Transport Device | 7-joint articulated optical arm |
| Laser Apparatus | Sealed off laser unit stimulated by direct current |
| Cooling System | Air |
| Power Supply | 220V/110V |
| Dimension of Machine | 55x45x108cm |
| Package Standard | 2 cases standard: Case 1: 68x56x125cm; Case 2: 80x40x30cm |
FAQ offractional CO₂ laser machine
▶ What is the difference between ablative and non-ablative fractional lasers?
Ablative fractional lasers generate coherent beams of light that are absorbed by human tissue and converted into energy. These beams are then applied across multiple wavelengths. In the targeted area, the energy heats up, causing tissue ablation (also known as vaporization). This approach is effective for deeper wrinkles, scars, and severe photodamage, but typically requires a longer recovery period.
Non-ablative fractional lasers are non-invasive laser treatments with a shorter recovery time. They stimulate collagen growth, improving skin tone and texture over time, but multiple treatments are typically required to achieve the same results.
Both ablative and non-ablative fractional lasers target only a small area of skin at a time, leaving untreated tissue, which speeds healing and reduces risks.
▶ What are the advantages of a fractional CO₂ laser machine?
Precision tissue removal: Creates controlled micro-ablative columns (MTZs) with adjustable depth and spacing.
Collagen remodeling: Triggers long-term collagen and elastin regeneration through thermal stimulation.
Faster healing: Untreated surrounding skin accelerates re-epithelialization and reduces downtime.
Customizable parameters: Clinicians can adjust fluence, pulse duration, and density to suit different indications and skin types.
Proven clinical outcomes: Effective for scars, wrinkles, pigmentation irregularities, and overall skin texture improvement.
▶ Who is a good candidate for fractional CO₂ laser treatment?
This treatment is suitable for individuals with:
* Fine lines and wrinkles due to aging or sun damage
* Acne scars or surgical scars
* Uneven skin tone and texture
* Stretch marks or enlarged pores
* Mild to moderate skin laxity
Ideal candidates are those with fair to medium skin tones, realistic expectations, and the ability to follow pre- and post-treatment care. Darker skin types may require adjusted settings to reduce the risk of post-inflammatory hyperpigmentation.
▶ How much does a fractional CO₂ laser cost?
Fractional CO₂ laser prices vary widely, depending on brand, clinical performance, and included features. Some low-end fractional CO₂ lasers can cost as little as $500 or even less, while high-end systems can cost as much as $60,000-$120,000. Well-known CO₂ laser brands, such as Lumenis (AcuPulse™) and DEKA (SmartXide²), maintain the same core technology—fractional CO₂ laser skin resurfacing—across multiple platforms. For some clinics and salons, the price of machines from major brands can be prohibitive.
We offer a more cost-effective alternative, providing the same essential clinical features, including adjustable energy, customizable scan patterns, and precise temperature control, at a more affordable price. Our fractional CO₂ systems are designed for clinics and distributors worldwide who demand high performance without the added cost.
For a detailed quote, comparison charts, or technical brochures, please contact our sales team directly. We will be happy to recommend the right configuration for your clinic and offer distributor-friendly pricing.
Configuration notice: Specifications, accessories, interface options and permitted uses vary by destination market and confirmed configuration. The Proforma Invoice, configuration sheet and model-specific documents supplied before payment take precedence.
Applications
Common applications for this model. Final protocols and suitability are confirmed for the selected configuration.
Technology
How this technology worksOutput power: 1-60W
Wavelength: 10.6μm, far-infrared laser
Display: 10.4 inch color touch LCD screen
Pulsed Radio Frequency: 0.530W
Spot Size: 0.01mm at the focus
Cooling System: Air
Wavelength
10.6μm,
Power
1-60W
Spot Size
0.01mm at the focus
Cooling
Air
Make this system fit your brand
Logo, boot screen, interface language, manuals and packaging can be evaluated for this model. Available items, MOQ and lead time are confirmed in the quotation.
- Machine logo or nameplate
- Boot screen and interface theme
- Interface and manual language
- Labels, manuals and packaging
Warranty & After-Sales, in Concrete Terms
The exact terms are printed on your Proforma Invoice before payment — no verbal promises.
Model-Specific Warranty
Duration, covered components and exclusions are confirmed in writing before payment.
Remote Engineer Support
Technical questions are coordinated by video call with factory engineers when needed.
Parts Plan Confirmed
Availability, price and dispatch method are confirmed for the selected model.
Operator Training Materials
Start-up guidance, manuals and available video materials are confirmed for the selected model.
How Ordering Works
See the full process- 1
Inquiry
Sales & technical coordination
- 2
Quote & PI
Written quotation
- 3
Deposit
Terms in PI
- 4
Production & QC
Test video sent
- 5
Ship & Support
Documents + training
Related Equipment
View allRequest a Quote for Fractional Co2 Laser Machine
Get pricing, shipping timeline and technical details for the exact model.