
Skin Tightening; Body Slimming
Cold Wave Shaping Instrument
Model: Cold Wave Shaping
The Cold Wave Shaping Instrument is an advanced non-invasive body contouring platform that integrates 2.45GHz microwave thermal lipolysis and contact cooling technology into one intelligent system.
Read the full overviewPricing
Available upon inquiry
Competitive factory-direct pricing
Why order from ZENLASE?
- Written quotation
- Certificate copies sent before you order
- Consumables & spare parts supplied long-term
- Operator training materials in the languages agreed for your order
- One contact from quote to after-sales
Product Overview
Working Principle
- 20% Energy for Dermis: Residual energy acts on the dermal layer, stimulating collagen regeneration to firm and lift the skin.
- Integrated Cooling Protection: While deep fat is heated, the system maintains the skin surface at40–42°C (or 5–20°C)via contact cooling, supporting a designed for improved treatment comfort and safe treatment experience.
Key Features & Advantages
1. Three-Depth Handpiece Versatility
- 15mm Handpiece: For stubborn fat (waist, abdomen, thighs, calves), deep fat layer dissolution.
- 7mm Handpiece: For body fat reduction, thick arms, and cellulite (orange peel pattern) improvement.
- 3mm Handpiece: For fine lines, skin tightening, and double chin reduction.
2. Precise 80/20 Energy Distribution
3. Non-Invasive & designed for improved treatment comfort
4. downtime depends on treatment settings and client response
5. Targeted Treatment for 10 Body Concerns
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Cold Wave Shaping Instrument |
| Microwave Frequency | 2.45GHz |
| Rated Power Supply | 100–240V AC, 50/60Hz |
| Handpiece Depths | 3mm, 7mm, 15mm |
| Skin Surface Temperature | 40–42°C (or 5–20°C) |
| Fat Cell Heating Temperature | Approximately 55°C |
| Control | Intelligent touchscreen + handpiece buttons |
| Operating Environment | Temperature 5–40°C, humidity ≤80% (non-condensing) |
| Storage Environment | Temperature 5–35°C, humidity 30–70% |
Treatment Areas & Handpiece Selection Guide
| Handpiece Depth | Recommended Area | Clinical Effect |
|---|---|---|
| 3mm | Double chin, nasolabial folds, facial sagging | Skin tightening, fine line reduction, facial lifting |
| 7mm | Arms, underarm accessory breast, thighs (shallow fat) | Fat dissolution, cellulite improvement, skin firming |
| 15mm | Waist, abdomen, thighs (deep stubborn fat), calves | Deep fat reduction, body contouring, orange peel pattern removal |
Before & After – What to Expect
- Immediately after treatment: Mild warmth on the treated area (normal, subsides within 1–2 hours). Some clients notice immediate skin firming.
- 2–4 weeks: Fat cells are gradually metabolized by the body; skin becomes smoother and firmer.
- 3 months: Maximum fat reduction effect is visible; collagen regeneration peaks for long-lasting contouring.
- 6 months+: Results remain stable; maintenance treatments are recommended for sustained effects.
- Cleaning: After each use, wipe the handpieces and host with a soft, damp cloth. For deep cleaning (weekly), use a cotton swab with a small amount of alcohol to clean interfaces.
- Storage: Keep in a dry, dust-proof cabinet at 5–35°C, humidity 30–70%. Avoid direct sunlight.
Cold Wave Shaping Machine FAQ
Why Choose the Cold Wave Shaping Instrument?
- One machine, three handpieces– covers facial lifting, body contouring, and cellulite improvement.
- 2.45GHz microwave technology– precisely targets fat cells while managing exposure to skin.
- 80/20 energy distribution– dual effects of fat reduction and collagen stimulation.
- Non-invasive & downtime depends on treatment settings and client response– safe and comfortable for clients.
Configuration notice: Specifications, accessories, interface options and permitted uses vary by destination market and confirmed configuration. The Proforma Invoice, configuration sheet and model-specific documents supplied before payment take precedence.
Applications
Common applications for this model. Final protocols and suitability are confirmed for the selected configuration.
Technology
How this technology worksMicrowave Frequency: 2.45GHz
Rated Power Supply: 100–240V AC, 50/60Hz
Handpiece Depths: 3mm, 7mm, 15mm
Handpiece Depth: Recommended Area / Clinical Effect
Power
100–240V AC,
Frequency
2.45GHz
Product Demonstration
Make this system fit your brand
Logo, boot screen, interface language, manuals and packaging can be evaluated for this model. Available items, MOQ and lead time are confirmed in the quotation.
- Machine logo or nameplate
- Boot screen and interface theme
- Interface and manual language
- Labels, manuals and packaging
Warranty & After-Sales, in Concrete Terms
The exact terms are printed on your Proforma Invoice before payment — no verbal promises.
Model-Specific Warranty
Duration, covered components and exclusions are confirmed in writing before payment.
Remote Engineer Support
Technical questions are coordinated by video call with factory engineers when needed.
Parts Plan Confirmed
Availability, price and dispatch method are confirmed for the selected model.
Operator Training Materials
Start-up guidance, manuals and available video materials are confirmed for the selected model.
How Ordering Works
See the full process- 1
Inquiry
Sales & technical coordination
- 2
Quote & PI
Written quotation
- 3
Deposit
Terms in PI
- 4
Production & QC
Test video sent
- 5
Ship & Support
Documents + training
Related Equipment
View allRequest a Quote for Cold Wave Shaping Instrument
Get pricing, shipping timeline and technical details for the exact model.



